Oracle Other Oracle Certification 1Z0-208

killtesは1Z0-208問題集を提供しております、killtesの製品Oracle Other Oracle Certification 1Z0-208 を使った後、お客様が認定合格にただ一歩の距離があります.まだ確信させませんか?今すぐkilltesの練習試験を試してみましょう。しかし、全部の解答を暗記によって、順調に合格することができると思います。
1Z0-208には、我々はお客様が成功に試験合格のために、一生懸命に努力してお客様に完全で均衡な公式を提供します、killtesのOracle認証 の質問と練習試験の製品は試す認定1Z0-208試験に自信を持ってお客様の能力を高めます. 一発合格することが保証できます。


1Z0-208

1.Which of the following opcodes is NOT implemented in the Business Process Tier?
A.PCM_OP_CUST_COMMIT_CUSTOMER
B.PCM_OP_ACT_ACTIVITY
C.PCM_OP_SEARCH
D.PCM_OP_RATE_ACTIVITY
E.PCM_OP_CUST_MODIFY_CUSTOMER
Correct:C


2.Which of the following statements about Opcode-to-function mapping is TRUE?
A.The config structure is included in the CMs pin.conf file
B.The fm_generic_config.c file is provided with Portal SDK as a template for opcode-to-function mapping
C.Each opcode macro name is mapped to one or more C functions
D.A and B
E.A, B, and C
Correct:D


3.Which of the following is NOT a valid error location for an error that occurred in the CM?
A.PIN_ERRLOC_CM
B.PIN_ERRLOC_FLIST
C.PIN_ERRLOC_PCM
D.PIN_ERRLOC_POID
E.B and C
Correct:C


4.________________ is a Service Integration Manager that integrates Portal with terminal servers
to support dialup Internet access service
A.Radius Manager
B.Content Manager
C.GSM Manager
D.EAI Manager
E.WAP Manager
Correct:A


5.Which of the following would you NOT find in the DMs configuration file?
A.Path and filename of Translation Manager shared libraries
B.Username and password for accessing external systems
C.Queuing manager parameters
D.Hostname and port number of the CM connecting to this DM
E.Database number for the DM
Correct:D


6.An array called PIN_FLD_ADDRESS is to be added onto the input Flist, input_flistp. The new
Flist pointer for the array will be called array_flistp. Which of the following provides the CORRECT
syntax for adding the array onto the input Flist?
A.PIN_FLIST_ELEM_ADD (PIN_FLD_ADDRESS, input_flistp, 1, &ebuf);
B.array_flistp = PIN_FLIST_ELEM_ADD (PIN_FLD_ADDRESS, input_flistp, 1, &ebuf);
C.PIN_FLIST_ELEM_ADD (input_flistp, array_flistp, PIN_FLD_ADDRESS, 1, &ebuf);
D.array_flistp = PIN_FLIST_ELEM_ADD (input_flistp, 1, PIN_FLD_ADDRESS, &ebuf);
E.array_flistp = PIN_FLIST_ELEM_ADD (input_flistp, PIN_FLD_ADDRESS, 1, &ebuf);

Correct:E


7.Which of the following statements INCORRECTLY describes the Object Tier of the Portal
architecture?
A.This tier can also be referred to as the Data Manager
B.One object tier can be used with multiple data tiers
C.This tier is used to translate Portal data into the format that can be processed by the Data Tier
D.This tier processes all requests coming from the Business Process Tier
E.This tier can also be referred to as the Translation Manager
Correct:B
8.All Portal opcodes are defined in the ___________________ file. An opcode corresponds to a
___________________. To write the code to implement the new opcode, you can use the
___________________ file as a template.
A.ops.h, function, fm_generic_ops.c
B.pcm_ops.h, function, fm_generic_opcode.c
C.ops.h, function, fm_generic_opcode.c
D.pcm_ops.h, program, fm_generic_ops.c
E.ops.h, program, fm_generic_ops.c
Correct:B