Overview
NX‑OS Release 10.3(4a)M provides supported software images, enhancements for selected platforms, known software conditions, and supported hardware for the Nexus 9000 Series.
Software Enhancements
This maintenance release does not introduce new software features, but includes enhancements for existing capabilities:
Platform and Scale Enhancements
-
Enhanced ISSU support for N9K‑C9408 for modular chassis.
-
vPC Scale Improvements:
-
Up to 98 on 9300‑FX2 platforms.
-
Up to 128 on 9300‑GX2 platforms.
-
Syslog Protocol Compliance
-
logging rfc‑strict 5424 fullcommand improves structured data and MSGID fields compliance.
Supported Software Images
-
nxos64-cs.10.3.4a.M.bin — supported on fixed and modular systems.
-
nxos64-msll.10.3.4a.M.bin — supported on modular systems with R‑series and R2‑series line cards.
32‑bit images are no longer supported.
Unsupported Features on N9K‑C92348GC
The following features are not supported:
-
VXLAN
-
Software/hardware telemetry
-
NetFlow/Analytics
-
iCAM
-
PTP
-
NX‑SDK
-
DME, Device YANG, OpenConfig YANG
-
gRPC, NETCONF, RESTCONF
NXAPI CLI and NETCONF over SSH remain supported.
Open Issues
Known software conditions include:
-
CSCwh76275 — 9364‑GX2A may discard multicast traffic; no workaround.
-
CSCwi92006 — FX2 platform interfaces may show 0 pps; no workaround.
-
CSCvz06811 — Data Broker switch floods IGMPv3 queries; workaround: filter IGMP with ACLs.
-
CSCwd75778 — gRPC port 50051 may fail in non‑default VRFs; no workaround.
-
CSCwd75851 —
/nxos/xlogmay fill on repeated config saves; workaround: avoid simultaneous saves. -
CSCwd41247 —
samcproxydeadlock may prevent tasks; workaround: debug access required. -
CSCwf13179 — VLAN filter with ACL ‘log’ may suspend VLANs; workaround: configure loopback.
-
CSCwf42887 — VXLAN storm‑control policer may not update after link flap; workaround: disable EVPN storm‑control.
-
CSCwf47425 — N9K‑C93600CD‑GX ports with QSA adapters may not forward; no workaround.
-
CSCwf48266 — Debug internal commands on FX2 may cause crash; workaround: contact support.
-
CSCwf67122 — MSDP unstable if VRF not enabled in BGP; workaround: enable VRF or disable BGP.
-
CSCwf67313 — Amber LED may light despite normal fan/PSU; no impact.
-
CSCwf70688 — API JSON for OSPF neighbors may misreport; workaround: use alternate query.
-
CSCwf73133 — High PTP correction values may occur on grandmaster failover; no workaround.
-
CSCwf75767 — Syslog messages persist even if not configured; workaround: reboot.
-
CSCwf84373 — Management interface shutdown may cause peer link flaps on FX2; no workaround.
-
CSCwf86821 — UDP relay ACL may misprogram; workaround: use command sequence and null route.
-
CSCwh01493 — Random detect burst‑optimized config may drop; workaround: remove commands.
-
CSCwh04496 — SNMP process crash may occur on 9508; workaround: disable SNMP.
-
CSCwh30962 — BGP Graceful Restart Helper may ignore BFD down events; workaround: shutdown neighbor before reload.
-
CSCwh32362 — EVORA crash on 9732C‑EXM; workaround: issue correct register via show command.
-
CSCwh37778 — Unsupported loopback may crash/reload; workaround: avoid unsupported commands.
-
CSCwh56979 — High CPU due to nxpython3 with LLDP; workaround: adjust LLDP logging.
-
CSCwh57443 — Missing syslog for PTP grandmaster change; no workaround.
-
CSCwh68484 — Power supplies may cycle; no intervention needed.
-
CSCwh72248 — vPC port‑channel may be inconsistent after reload; workaround: remove switchport monitor.
-
CSCwh74734 — Tahusd crash on 93108TC‑FX3P under rare conditions; no workaround.
Resolved Issues
-
CSCwf34104 — SMU may not activate after reload/panic; workaround: reload to commit SMU.
-
CSCvw16064 — Syslog now uses NILVALUE for STRUCTURED‑DATA and MSGID to comply with RFC 5424.
Supported Platforms
Modular Switches
Line Cards and Fabric Modules
Supervisor and Controller Modules
Fans, Accessories, and Power Supplies
Fixed Switch Platforms
Compatibility and Operational Notes
Perform software upgrades and downgrades per NX‑OS procedures. Licensed features may continue in honor mode after downgrade. Review supported optics and cabling before applying software changes.