The BP-S510 has a sophisticated design that provides simple, user-friendly operation. Its advanced functionality makes it perfect for a wide variety of uses, including post-anesthesia care, ambulatory surgery, endoscopy, emergency rooms and more!
•Measures ECG (3/5 lead), heart rate, Colin NIBP, Nellcor SpO2 and respiration. Available with temperature, two-channel IBP, EtCO2, and a printer.
•Compact: Conveniently compact and feature-packed, the BP-S510 is great for areas where space is at a premium.
•Lightweight: Weighing only 12.1 lbs, the BP-S510 with battery such as Colin BP-88 Battery
, Colin BP-88S Battery
, Colin BP-308 Battery
, Colin BP-508 Battery
, Colin BP-608 Battery
, Colin LC-T121R8PU Battery
, Colin LC-SP122 Battery
, Colin WP1250 Battery
, Kenz Battery
, Kenz Cardico 302 Battery
, Kenz 10TH-1800A-W1 SU Battery
, Philips 989803144631 Battery
is easy to carry from ward to ward. This lightweight device makes it easy to move to stepdown, PACU, RR, etc.
•Battery Operation for Portability: Available with rechargeable batteries, the BP-S510 can be used during transport within your facility.
•Wide Viewing Angle: The BP-S510’s large LCD screen features a wide viewing angle. Each parameter is color-coded in bright and vivid colors, making the information easy to read even from a distance. You can also select from multiple views to highlight just the information you need.
Technical Specifications
Non-Invasive Blood Pressure (NIBP) - Patented Colin Technology
•Measurement technology Oscillometric method
•Measurement method Linear deflation method
•Pressure display range 10 to 300mmHg
•Pressure display accuracy Less than ±3mmHg
•NIBP Measurement range
•Adult/pediatric mode
SYS 60 to 250mmHg
MAP 45 to 235mmHg
DIA 40 to 200mmHg
Pulse rate 40 to 200bpm
•Pulse rate 40 to 240bpm
•NIBP accuracy AAMI SP-10:2002+A1:2003
•Pulse rate accuracy ±2% or ±2 beats
Power Requirement
•AC Power 100-240V~50/60Hz, 0.5-1.3A
•Battery Ni-MH, 12V/3.8Ah (1 included)
ECG (Electrocardiogram)
•Leads 3/5 Lead
•Lead I, II, III, aVR, aVL, aVF, V (Chest Lead)
•Heart Rate
•Measurement Range 20 to 250bpm
•Accuracy ±3bpm or ±5% (whichever is greater)
General
•Dimensions 360(W) x 215(D) x 280(H)mm (14.2 x 8.5 x 11in)
•Weight 5.5kg (12.1lbs) (excluding optional configurations and accessories)
•Display - Screen Size 26.4cm (10.4in) measured diagonally, Screen Type/Color Liquid Crystal Display (LCD) color, Resolution 800 x 600 pixels
•Number of traces 4 or 6 waveforms
•Safety Standard IEC60601-1:1988+A1:1991+A2:1995
•Degree of protection (enclosures) IP21
•Type of protection Type CF - Applied part
Accessories
Most models: Reusable adult cuff, adult 3.5m cuff hose, ECG cable,
ECG 3-lead wires, SpO2 Durasensor® DS-100A, SpO2 extension cable
DOC-10, operation manual, power cord, rechargeable battery (1).
Available with: CO2 sampling set, printer paper, ECG 5-lead wires,
temperature probes, rolling stand, and a full size range of reusable and