lynette012@outlook.comのブログ -6ページ目

lynette012@outlook.comのブログ

ブログの説明を入力します。

 oil should be used in the field of strokes to write


 or at the surface of the charred and then mop with water after leaving traces to test whether, if the water is of poor quality mop left traces of nonconforming After mop to maintain the original effect, leaving no traces and maintain high-quality high-definition quality products.
Flatness
(7) of azul cielo marble, you should use high-precision laser displacement sensor test can also be summarized by visual appraisal to determine the various views in the field, because the relative flatness, with little overall effect waves qualified, otherwise unqualified .


(8) Stone-definition, should be used to measure the clarity instrument can also be used to measure density gauge, stone from granite slab supplier, ceramic surface, the higher the density the higher the resolution, the views can also be identified by aggregating multi-resolution, high-definition visual available the whole surface of the glass phase fully reflect the high definition should be established, without the slightest sense of Xia hazy fog, no orange peel, no pitting, 100% fully reflecting the interior ceiling, chandeliers, lamps barrel, slightly to the filament can reflected reflecting effect. This is the definition, otherwise it can not be regarded as clear. This is a visual standard.


(9) stone cover, which can also be interpreted as fullness or thickness, should be in the visual field of the ground pinholes, smaller cracks are completely covered, completely covered into a plane, fullness, thickness to achieve the high-quality products, but also visually see hairline cracks, pinholes but not see, fullness, thickness obviously not enough for qualified products, pinholes, small cracks can still see, not to mention what it fullness, thickness, and this for inferior unqualified.


past industry has been falsely misleading use of the photometer, that is the only criterion for the detection of g682 granite slab, ceramic finishes Quality. Obviously very wrong kind of misleading, there is a problem when the focus is a very responsible for the performance, is upside down. Stone, ceramic care is actually very minor bright finishes, which includes many substantive issues is the focus of the course, and 9:00 are in actual use mentioned above must. Photometer to measure it, but by the amount of light or a reflectance, from this point we can understand the greater reflectivity caused by strong light refraction, the more intense the refraction of light, the stronger the light pollution, for our children and grandchildren descendants of healthy growth, we should work together to resist light pollution, we advocate is a high-definition, low reflectivity, boycott light pollution, build a green environment. The EU already has a new ordinance to light pollution legislation, regardless of interior and exterior walls, floors light reflectivity part can be greater than 80 degrees, where beyond this range is defined as light pollution, because the reflectance value, the more intense the more big light pollution, construction side must accept to heavy penalties.


stone quality must be: light without Yao, profit and not slippery, Ming Jing thorough, high-resolution, low reflectivity, boycott light pollution, green, listen to digital to see results, with your eyes do the talking.